The flat roofing material must go up the wall a minimum of 12 or up the wall and over the top of the wall if the wall is less than 12 high.
Roofing against wall.
Galvanized sheet metal bent at a 90 degree angle i e.
Follow the photo for illustrated instructions.
If the roof runs flat up against the brick wall you must install the roof side of the flashing either under the last layer of shingles or over the roof material if it is metal.
Below are two photographs of roof wall step flashing completed and effective of a slate roof against a brick wall below left and in process with step flashing against a dormer sidewall before the dormer siding has been put in place below right.
Bent into an l shape.
Here is an attempt though maybe not a very good one to make the roof flashing serve also as a through the wall flashing with a tile roof.
This flashing is typically field fabricated from a sheet of 26 ga.
Proper roof wall abutment flashing examples.
Flat roof and flashing against brick wall install base flashing under shingles or over metal roofing material.
For areas where the walls meet the roof you will need to use the step flashing technique.
Posted march 4 2017 filed under roof installation roof repair maintenance.
Step flashing is used to provide a water tight connection where roofing adjoins a vertical juncture.
Metal flashing also called roof flashing goes against a stucco wall to protect it from water damage.