Depending on which kind of stove pipe you use single wall or double wall you must also account for proper clearances from combustibles.
Single wall flue pipe in attic.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
Single wall flue vents require a six inch minimum of clearance to combustibles and b vent double wall requires minimum 1 inch clearance.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
The proper term for this connector is a flue vent connector but plenty of normal people use the word flue or the phrase stack pipe loosely for any sort of chimney or chimney connector.
Single wall vent pipe must be connected with 3 sheet metal screws at each joint.
Metal flue fire clearance requirements single wall metal pipe flues oil fired equipment.
Of duraplus chimney pipe sold separately and features the necessary.
It also looks very different from the obvious single wall pipe that runs from the boiler to the point where the flue pipe enters the ceiling at the first floor.
The duraplus system from duravent is designed to the duraplus system from duravent is designed to stay cool on the outside provide a hot draft on the inside and boost stove efficiency offering a fire safe design that protects both the chimney and building.
A sealed double wall flue pipe is effective at retaining the heat in the flue gases because the air space between the inner liner and outer shell acts as.
There are two general types of double wall flue pipes.
This can be a problem when the flue runs into your attic on its way to the roof as it can heat your attic.
There are two general types of double wall flue pipes.
A sealed double wall flue pipe is effective at retaining the heat in the flue gases because the air space between the inner liner and outer shell acts as.
Once the venting reaches the wall or ceiling it must be converted to class a chimney pipe.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
A single wall metal flue vent is not safe if it passes through combustible floors walls ceilings roofs.
The flue pipe looks to be a double wall pipe as it has some type of special locking tabs at the ends.